REP-F feedback electronic load
REP-F feedback electronic load
▲REP-F Series DC Feedback Electronic Load
The REP-F series DC feedback electronic load is a power supply developed for fuel cell stack and engine system testing. The power supply is based on the power frequency isolated IBGT two-pole conversion architecture power electronic converter. DC electronic load for high reliability, programmable, and automatic operation. With high precision and high dynamic response, the input DC energy full power segment can be fed back to the grid. It satisfies the low voltage and high current test and is used in test fields such as fuel cell stacks and fuel cell engine systems.

▲Technical indicators:
Feature type |
Parameter item |
Technical Parameters |
The input parameters |
Number of phase |
Three phase four wire +PE |
voltage |
Phase voltage: 220V 10%, line voltage: 380V 10% |
|
frequency |
50/60Hz±5Hz |
|
Isolation function |
Built-in isolating transformer (optional) |
|
Input power factor |
0.99 |
|
Input current distortion |
3% |
|
Output parameters |
Rated power (kW) |
custom |
Peak power (kW) |
custom |
|
Peak power time (S) |
60 |
|
Rated voltage (V) |
custom |
|
Rated current (A) |
custom |
|
Voltage accuracy |
Resolution 0.1v |
|
Accuracy of current |
Resolution 0.1a |
|
Source effect |
0.1%F.S |
|
Effect of load |
0.1%F.S |
|
Ripple (Vpp) |
0.2%F.S |
|
Transient recovery time |
5ms |
|
Current rise time |
10ms (10%~90%, resistive load, test conditions: power output, load on test) |
|
Forward and backward switching time |
10ms (+90%~-90% switching) |
|
Protection function |
IGBT overheating, IGBT over-current, transformer overheating, input over-voltage, input under-voltage, bus over-voltage, output over-voltage, output over-current |
|
Feedback parameters |
Three-phase line voltage |
380v15% (allowable grid voltage) |
frequency |
50 10% (allowable grid frequency) |
|
The power factor |
0.99 (standard AC source input, distortion within 1.5%) |
|
Total harmonic content |
3% |
|
Feedback function |
100% energy feedback |
|
According to |
Large screen color LCD |
|
Stop function |
Equipped with emergency stop button |
|
Soft start |
Precharge function |
|
Isolating transformer |
optional |
|
Communication interface |
RS485, CAN (optional) |