Copyright © All Rights Reserved Yangzhou Dinghua Electronics Co., Ltd.
苏ICP备11029078号-1 Powered by www.300.cn
Sales Hotline:
0514-87664485
0514-87662866
0514-87665188
0514-82361988
Fax:0514-87662068
E-mail:sales@cdhe.cn
PVA Series Programmable Solar Cell Analog Power Supply
PVA Series Programmable Solar Cell Analog Power Supply
▲PVA Series Programmable Solar Cell Analog Power Supply
PVA series solar cell analog power supply adopts DSP digital control technology. Power inverter adopts new soft switch and low loss rectification technology. The power efficiency is over 95% in the wide voltage power output power range, with low ripple, high power density, dynamic With good characteristics and advanced process, it can simulate the condition of various solar panels (such as thin film batteries) under different weather conditions based on solar panel information.
▲Product performance characteristics:
• Adapt to a variety of photovoltaic panel types: single crystal, polycrystalline, amorphous, etc.
• Output mode MTTP mode and constant voltage, constant current, constant power output mode.
• Basic functions for universal test DC power supply programming.
• Automatic programming to control I-V curve output
(You can automatically program any number of curves and run by time)
• Simulate different types of solar array I-V curves
• Simulate I-V curves at different temperatures and light intensities
• Simulated PV array local shadow occlusion I-V curve
• Simulated scaling of I-V curves under full-day sunshine
• Static and dynamic MPPT performance test
• Simulate all-day cumulative energy metering
• High output current and voltage accuracy
• The conversion efficiency is as high as 95% or more, and the total harmonic THD is less than 5%, which has less harmonic pollution to the power grid.
• High degree of intelligence: friendly man-machine interface, LCD large screen display, curve, programming at a glance, touch operation, automatic data storage. The output can be configured with USB / RS232 / RS485 control interface, which can be operated by the local machine or by the host computer software.
|
▲Product use occasion
Production, detection and aging of photovoltaic grid-connected inverters, simulation of solar cell characteristics, simulation of power battery characteristics, etc.
▲Customer Testimonials:
Hefei Sunshine Power Co., Ltd., Shanghai Meike New Energy Co., Ltd., AVIC Group Shanghai Hangrui Power Co., Ltd., Anhui Yihe New Energy Co., Ltd., Suzhou Aisuo New Energy Co., Ltd., Jiangsu Zhaofu, Jiangsu Shidian, Jiangsu Linyang Group, Xi'an Longteng New Energy Technology Development Co., Ltd., Hangzhou Jinbei Electronics Co., Ltd., Jiangsu Zhonghang Power Control Co., Ltd. . . . . .
▲The main technical parameters
Programmable power supply |
10KW |
32KW |
200KW |
500KW |
Input voltage |
3*(360-440)VAC (rated output) 3L+PE (no zero line) 48-62Hz |
|||
Input Current |
3*20A(rsm) |
3*60A(rsm) |
3*430A(rsm) |
3*950A(rsm) |
Leakage current |
<10mA |
|||
Voltage regulation (CV) |
0—100% Umax Umax value DC current rating of 52, 65, 100, 200, 400, 500, 600, 800, 1000V, as required, |
|||
Current regulation (CC) |
0—100%Imax (selected according to customer's required power level) |
|||
Power regulation (CP) |
5—100%Pmax |
|||
Efficiency (rated power) |
92% |
93.5% |
95% |
95% |
Source effect |
<±0.1% of rated value (measured at rated output power) |
|||
Load effect |
<±0.1% of rated value (measured at rated output power) |
|||
Output ripple rms |
<0.4% FS rating (measured at rated output power) |
|||
Output ripple peak-to-peak |
<3% rating (measured at rated output power) |
|||
Soft start |
>3S |
|||
Transient response time |
4mS |
|||
Power factor |
>0.92 (full load) |
|||
Display accuracy |
LCD liquid crystal display (accuracy is determined according to customer requirements) |
|||
Protection method |
Overcurrent, overvoltage, phase loss, short circuit automatic protection |
|||
Way of working |
Long-term full load continuous operation |
|||
Insulation resistance |
>200M |
|||
Control interface |
RS485 or RS232 standard interface (optional) |
|||
cooling method |
Forced air cooling |
|||
Volume (reference value) |
10kW: 444 (19 inches) wide * 264 (6U) high * 495mm deep |
|||
Weight (reference value) |
35kg |
68kg |
480kg |
1100kg |